What's New in the Latest Release
Before April 2010
Version 1.4.0.1
- Automatic and Manual check for software updates
- Camera Wizard for easy camera setup and configuration
- Monitor and Control of VPU Status
- VPU Configuration Tool
- Max number of identified segments increased from 255 to 2000
- Support for new Advanced Synch Unit
- Support for Fastec SportsCam and Troubleshooter LE
- Uniform new version numbering
Version 1.3, January 2010
- Save and Load Workspaces Associate file extensions with MaxPRO
- Default Marker List in Marker Options Tab
- On-Line Support Resources from Help Menu
- Improved AVI File Import using a common dialog for all cameras
- Analog Inputs
Version 1.2
Process- ing Workspace Tab Added. This tab is used to apply post processing to the data. Currently MaxPRO can transform marker data into a local coordinate system defined by 3 markers and/or apply a translation to the marker coordinates.
- Analysis Screen added. You can plot Position vs Position and Position. Velocity, Acceleration and Residuals over Time.
- Improved Camera Error Handling
Version 1.11
- Record Video option. Allows you to save the recorded video along with the 2D/3D marker data. The video9s) can be viewed in the 2D camera views. A "v" will be displayed next to the camera number if a video was recorded. To enable a camera to save the video, use the Camera tab in the workspacebar and enable the Record Video option. Video files are stored in a separate file with the extension Cam_n.avi added to the file name. A link in the moc (c3d) is maintained to the video files.
- Options dialog has been added. This allows you to set various program options and properties.
- A DHCP Server has been added. It is recommended to use DHCP for any Ethernet based cameras. If you're not connected to a network with a DHCP server you can use the supplied server. It can be started with MaxPRO and run in application mode or it can be installed as a service. For most installation, running the server in application mode (Start with MaxPRO) is recommended.
- The File Tab in the workspacebar has been enhanced.
- Diagrams and drawings are accessible from the help menu.
- Interpolation bug fixed.
Version 1.1
- 2D Camera Views have been added to the Tracking/Viewing Screen. The 2D Views are only available when the file has 2D data present.
- Beta status removed
Version 1.0-008 Beta 4
- Added External Sync to Master Camera Setup. This is used when an external clock is being used as system clock/sync. This must be used with the Fastec Inline cameras and the clock output connection.meout
Version 1.0-007 Beta 4 - Changed from using localhost as default to 127.0.0.1 for Vista systems that doesn't have localhost defined.
- Import of AVI fixed so it doesn't use long timeout
Version 1.0-006 Beta 4 - Added Delete 3D point. Use this to remove bad 3D point or to trim a 3D segment. If the point is at an end point of a segment then the segment will be trimmed, otherwise the point will be marked as invalid.
- Added Undo command. Undo works on most editing commands such as identify, stick, delete point and hide segment.
After April 2010
Version 1.4.2.1 through 1.6.4.1
- FIXED: Incorrect Lens written to MOC file
- FIXED: Can't save video when viewing video
- FIXED: Sometimes the V doesn't show up ???
- FIXED: Locks up when opening file from recorder
- FIXED: Stick Figures in wrong direction
- FIXED: Processing Marker Names doesn't change when renaming markers
- FIXED: Open MOC File, Save to ASCII and it will ask to save when closing file
- FIXED: Must Expand Ports in Camera Setup to change port numbers
- FIXED: If require calibration option not set, then it is not showing correctly in options
- FIXED: If go to record and record is disabled due to calibration status and then go to calibration the record status is still disabled
- FIXED: Sometimes camera 5&6 don't update their window after start record to display dark gray window.
- FIXED: Can't create files with more than 255 unidentified segments due to C3D limitation
- FIXED: Camera previews flash. It also takes a long time before markers start showing up. Looks like it sometimes reads without getting anything back
- FIXED: Sometimes camera 1 don't show tracking preview when using 5/6 cameras
- DONE: Backup of Registry Key(s)
- DONE: Save and Load Camera and Recorder Settings to INI from WS Toolbar
- DONE: Save and load workspace
- DONE: Associate file extensions with MaxPRO
Must text under Windows 7 - DONE: Default Marker List in Marker Options Tab
- DONE: On-Line Support resources from Help Menu (with new website)
- DONE: Improved AVI File import using a common dialog for all cameras
- DONE: Remove Noise setting from tracking and use Low, Normal and High speed settings for acceleration
- DONE: Camera Setup Wizard
- DONE: VPU Tray Application
- DONE: Must have some kind of External Trigger forced flag
- DONE: VPU Configuration Tool
- DONE: Analog
- CHECKED: Need to make sure that analog is included in WS
- DONE: Load and Save Analog WS
- DONE: Analog Options Dialog with new NoStop option
- DONE: Update Analog MoCap Table and Create Labels and Descr in C3D
- DONE: Use Labels from File when loading in TrackView
- DONE: Export Analog
- DONE: Can't preview video while recording (disable record when video preview)
- DONE: Exposure not initialized correctly with Basler and VPU
(sometimes timeouts when adjusting exposure and preview is on) - DONE: User Interface Update and Wait for Trigger must be improved. Sometimes a camera view is grayed during tracking ?
- DONE: VPU LEDs not showing when started as maximized
- DONE: Run Camerawizard without new workspace
- FIXED Crashes on Exit if recorded (and have analog ?)
- FIXED: Analog
- Edit Analog Names
- Be able to select channels to view ?
- Need to be able to scale and zoom etc.
- DONE: Must Add Default Marker List
- FIXED: Camera init Progress not working after an Error
April-June 2017
- DONE: Rotated Camera Views (probably should be done in CamView)
- DONE: Marker List Editor
- DONE: Tooltip Description when hoover on Markers
- DONE: Gradient Colorizer DONE: Auto Advance/Reverse on Invalidate (Alt+Del)
- DONE: Interpolate All/Colorize from Point Table Header Menu
- DONE: Implement T0 and T1 (Export only between these)
- DONE: Pos/Vel/Acc vs Time Graphs should use First and Last Frame
July 2017
- DONE: Filters
Write filtered data to C3D Fid section. Flag any Segments as SEG_FILTER. Segs that are filtered will read data from Fid instead of XFid section. Unfilter will simply remove SEG_FILTER status from segments - DONE: Command Qualifiers /ANALYZE /TRACK /RECORD/CALIBRATE
- DONE: Initial Graph View
- DONE: Unidentify, Filter and Interpolate from Tools Menu
- DONE: Select/Hide Using Wild Card Characters
- DONE: Delete Available Segments
Flag the segment as deleted in the status field. Add a Deleted Segments Table that can be selected instead of Available Segments Table by double-click on Available Segment Header. This will display the deleted segments and the user can undelete any of these. - DONE: Quick ID: Don't deselect marker when clicking outside a marker while in QuickID mode
- DONE: Disable application of multiple filters on markers
- DONE: Split Segment
- DONE: Implement Camera Present graph (or numeric or…)
- DONE: Autorange valid frames
This will look for frames with all markers valid and set first and last frame - DONE: C3D option to select range
Option in General Options implemented to allow selected range to be used when creating C3D file - FIXED: When Splitting then SEGMENT:TABLE needs to be extended ?
- FIXED: Load Tracking WS the inter/filter pars are incorrect
July 2022
- DONE: MaxD3DX – Show Cameras
- FIXED?: Dbl-Click on CameraView is messed up sometimes
- FIXED: Frame Rate in Calibration and Recording must be different
April 2023 – v1.6.4.5
May 2023 – v1.6.5.3
- Spinner on Recording Time
- Delayed Start in Recording
- Anti Alias and Object Resolution in D3D Properties Tab
- Default Marker Names Option and Use Default Marker Names Right-click option
- Show Camera information in File Info Tab
- MaxD3DX 3D Trajectories
- FIXED: OnOnPreviewStateCamviewctrl when Video/Marker preview is toggled using right-click menu
- FIXED: Outdated link to WhatsNew.htm corrected
June 2024 – v1.6.5.5
- NEW: Expand/Collapse All of Identified Markers in Points Table
- NEW: Open and Display/Analyze MOC files created by MaxREAL
- FIXED: Website Link on Splash Screen was not secure (https)
- FIXED: Bug causing an error while trimming overlapped segments when identifying